Home | Sitemap
deutsch | français | italiano | 日本語 | 简体中文
Hilscher Gesellschaft für Systemautomation mbH
Rheinstraße 15
65795 Hattersheim
Germany

Telephone:
+49 (0)6190 9907-0
Facsimile:
+49 (0)6190 9907-50

E-mail:
info@hilscher.com

Sign up for the Hilscher e-Newsletter and you will receive regular updates on Hilscher products and company information.

PC Cards

Field bus integration for PC-based systems

  • All PC card formats
  • All leading fieldbus systems
  • Identical ‘easy to use’ APF as on CIFs and on the EC1
  • Direct access to the process data in the dualport memory
  • One configuration and diagnostic tool
  • Online diagnostic interface
  • LED status display
  • FLASH memory for the configuration data
Today, the PC assumes a key position in automation technology. Together with a real-time operating system, e.g. Windows® NT, it creates an ideal hardware platform for control and visualisation of process data. By using so called SoftPLCs the PC penetrates into application areas that have been the domain of classical programmable controllers.

Fieldbus systems with remote input and output modules are used for the data transfer between the PC and the automation equipment. We offer special interface cards since the PC does not feature a direct link to the fieldbus.These intelligent cards manage the entire data transfer. Only useful data are passed onto the user applications.

The idea behind our ‘Communication Interface’ CIF®, is to present a common access to the various fieldbus systems available on the market. We supply a powerful, easy to handle and reliable solution at low-cost. Thus, you can concentrate on your applications and need not 're-invent the wheel' when you are going to use a different fieldbus system tomorrow.

We place special value on ease of operation. This includes a loadable Firmware, configuration data that remain even with a power failure, an online RS232C diagnostic interface and LED status indicators. Naturally, each card supplied carries the CE mark.


Field bus connection made easier

With a CIF card as a field bus Master one always obtains a current process depiction of all configured Slave devices.
With a CIF card for a field bus Slave communication, the Dual-Port memory of the card serves as a process depiction, which can be accessed from the field bus Master as well as from the application.

In both variants, the application program need not concern itself with the actual field bus communication as this task is taken over by the CIF card thanks to its own communication processor.



PC cards in all formats for all fieldbus Standards

We supply PC cards with ISA- or PCI-bus, Compact PCI or in the PC/104 and PC/104P format and as PCMCIAcard for all leading fieldbus systems. Careful component selection and concentration of the necessary functions enable a single-sided surface mount card at a low-cost.

Fieldbuses differ from each other in their physical interfaces and capacity spectrums. We do not use plug-in modules for adaptation. We provide a dedicated card for each fieldbus system, sometimes different ones for Master or Slave functions. Only in this way can we guarantee you the best price/performance relationship with the highest degree of reliability.



Fieldbus ISA CIF 30 PCI CIF 50 PCMCIA CIF 60 Compact CIF 80 PC/104 CIF 104 PC/104+ CIF 104P PMC
AS-Interface-Master ASIM ASIM ASIM   
CANopen-Slave
CANopen-Master
COS
COM
COS
COM
COS
COM
COS
COM
COS
COM
COS
COM
COS
COM
Ethernet EN EN DNS
DNM
InterBus-Slave
InterBus-Master
IBS
IBM
IBS
IBM

IBM
   IBS
IBM
     
Modbus Plus MBP   
PROFIBUS-DP-Slave-
DP/FMS-Master
DPS
PB
DPS
PB
DPS
PB

PB
DPS
PB

PB
  
Protocol yes yes yes DPS
PB  
SERCOS
-passive
   SCM
SCEB
        
SCEB
     


System Configurator with a uniform ‘look and feel’

All cards are configured using the SyCon® System Configurator. This has been coded in C++ and executes under the Windows® 95/98/ME and Windows® NT/2000/XP operating system.
Graphical input of the individual bus participants, clearly structured menu guidance and automatic computations of the bus parameters make the configuration a very simple exercise.
By means of the function interface, other programs can exchange data with the configurator and access its database.
The configurator can also be included in the customer\'s own product as an OEM version.



Driver for all Windows® operating systems and Linux

We supply a 32 bit Device Driver, since you cannot access the hardware directly with modern operating systems. This driver has the same functional interface as our drivers for DOS. Thus you can access the Communication Interface using the same C interface for all operating systems. In addition there are drivers for various visualisation systems and all leading SoftPLCs.









An OPC Server for all fieldbus systems

Today, OPC is the standard interface for exchange of process data between PC applications. We supply an OPC Server for all our PC cards. If your visualisation is functioning as an OPC client, there will be no difference for you between the individual fieldbus systems or PC cards.



Uniform and ‘easy to use’ application interface

The data exchange between the application and the Communication Interface takes place via a dual-port memory. This is a type of memory where read/write accesses are performed both from the application and from the interface side. A static data model is used for the dual-port memory. It is uniform for all cards and contains the process image. Commands and message oriented data are exchanged using two mailboxes. The entire handshake is performed in either polling or interrupt mode using only two bytes. This is described in detail in our free Tool Kit and illustrated by example programs. Thus, you are able to code your drivers in the shortest possible time.




Copyright 2012 - Hilscher Print this page | Imprint